| Water Electrolysis Hydrogen Generator Bipolar Technology for High Pressure & High Flow rate | Contact Us: +91 (011) 49997000 Send Enquiry |
Bipolar Water Electrolysis Hydrogen Generator Basics
Capacity: 5 NM3/hr to 500 NM3/hr
Purity: 99.8% to 99.999%
Pressure: Up to 15-Bar without Hydrogen booster compressor; 200 Bar with booster for cylinder filling
Dew Point: Up to (-) 80˚C
| Water Electrolysis principle | Send Enquiry |

Transformer and Rectifier provide input power as per electrolyzer requirement. In big size hydrogen plants input power to transformer is at 3.3 KV or 6.6 KV or 11 KV. While in sizes up to 25 NM3/hr, 400 Volts LT power supply is used. MVS Bi-Polar electrolyzer is where high purity DM water is broken to H2 and O2. Hydrogen is evolved on cathode side of cells and Oxygen on anodes of cells. This design makes Electrolyzer unit very compact in size. Hydrogen & Oxygen come out separately from cells into Hydrogen separator and Oxygen separator. Then these are cooled in heat exchangers by cooling water and separated from electrolyte by gravity. Then gases are washed by DM water. Finally clean gases come out through de-misters which are located on top of washers.
| Compact Modular design | Send Enquiry |

Low power consumption
Besides DM Water, power is the single main utility requirement and it is paramount that power consumption be kept to a bare minimum. Hence, in our design power consumption only 4.6 KW per M3 of Hydrogen. At this low power consumption, our design is one of the most efficient generator in the market.
Additionally, since our Hydrogen plants produce gas directly at 15-Bar pressure, for several processes there isn't a requirement of a booster compressor.
Reliable Purity
For many processes where Hydrogen is required, consistent purity is very important. Our generators are designed to deliver high (99.8% with 0.2% Oxygen) purity and very high purity (99.9999% with 1-ppm Oxygen) with the use of an additional purification unit. The consistent purity is maintained in the system by total automated operation and online Oxygen gas analyzers continuously indicate Hydrogen purity.
| Ultra-safe operation | Send Enquiry |
Safe operating environment
In our design, there is no Air pollution and no fumes. Electrolyte is in closed cells so there are no fumes in the atmosphere. This also prevents blow off gases and there is no spillage of electrolyte.
Your Enquiry
Give us the opportunity to discuss your requirement in detail. Please send us your enquiry here.